ADE9078 High Performance Polyphase Energy Metering AFE

The ADE9078 is a highly accurate, fully integrated energy metering device. Interfacing with both current transformer (CT) and Rogowski coil sensors, the ADE9078 enables users to develop a 3-phase metrology platform, which achieves high performance for Class 1 up to Class 0.2 meters.

The ADE9078 integrates seven high performances ADCs and a flexible DSP core. An integrated high end reference ensures low drift over temperature with a combined drift of less than ±25 ppm/°C maximum per channel, each of which includes a programmable gain amplifier (PGA) and ADC.

The ADE9078 offers an integrated flexible waveform buffer that stores samples at a fixed data rate or a sampling rate that varies based on line frequency to ensure 64 points per line cycle. These two options make it easy to implement harmonic analysis in an external processor according to IEC 61000-4-7.

Two power modes are provided to enable detection of meter tampering: PSM2 uses a low power comparator to compare current channels to a threshold and indicates whether it is exceeded on the IRQ0 and IRQ1 outputs; PSM1 enables fast measurement of current and voltage rms (xVRMS and xIRMS), active power, and VAR during a tamper.

The ADE9078 allows advanced and highly accurate energy measurements, enabling one platform to cover a wide range of meters, through a combination of various high end metrology features and superior analog performance.

Applications
  • Polyphase meters
  • Power quality monitoring
  • Protective device
产品特点和性能优势
  • 7 high performance analog-to-digital converters (ADCs)
    • 101 dB signal-to-noise ratio (SNR)
    • 10,000:1 dynamic range
    • Wide input range: ±1 V, 0.707 V rms full scale
    • Differential inputs
  • 101 dB signal-to-noise ratio (SNR)
  • 10,000:1 dynamic range
  • Wide input range: ±1 V, 0.707 V rms full scale
  • Differential inputs
  • ±25 ppm/°C maximum channel temperature drift (including ADC, internal VREF, and PGA drift) enabling Class 0.2 meters with standard external components
  • Power quality measurements
    • Line frequency: 1 measurement per phase
    • Zero crossing detection, zero-crossing timeout
    • Phase angle measurements
  • Line frequency: 1 measurement per phase
  • Zero crossing detection, zero-crossing timeout
  • Phase angle measurements
  • Supports current transformers (CTs) and Rogowski coil (di/dt) sensors
    • Multiple range phase/gain compensation for CTs
    • Digital integrator for Rogowski coils
  • Multiple range phase/gain compensation for CTs
  • Digital integrator for Rogowski coils
  • Flexible waveform buffer
    • Able to resample waveform to ensure 64 points per line cycle for ease of external harmonic analysis
    • Events can trigger waveform storage
    • Simplifies data collection for IEC 61000-4-7 harmonic analysis
  • Able to resample waveform to ensure 64 points per line cycle for ease of external harmonic analysis
  • Events can trigger waveform storage
  • Simplifies data collection for IEC 61000-4-7 harmonic analysis
  • Advanced metrology feature set
    • Total active power, volt-amperes reactive (VAR), volt-amperes (VA), watthour, VAR-hour, and VA-hour
    • Fundamental VAR and VAR-hour
    • Current and voltage rms per phase (xIRMS, xVRMS)
    • Supports active energy standards: IEC 62053-21, IEC 62053-22; EN50470-3; OIML R46, ANSI C12.20
    • Supports reactive energy standards: IEC 62053-23, IEC 62053-4
    • High speed communication port
    • 10 MHz serial peripheral interface (SPI)
  • Total active power, volt-amperes reactive (VAR), volt-amperes (VA), watthour, VAR-hour, and VA-hour
  • Fundamental VAR and VAR-hour
  • Current and voltage rms per phase (xIRMS, xVRMS)
  • Supports active energy standards: IEC 62053-21, IEC 62053-22; EN50470-3; OIML R46, ANSI C12.20
  • Supports reactive energy standards: IEC 62053-23, IEC 62053-4
  • High speed communication port
  • 10 MHz serial peripheral interface (SPI)
  • 模数转换器 (ADC)
    设计工具
    数据手册
    文档备注
    ADE9078: High Performance, Polyphase Energy Metering AFE Data Sheet (Rev. 0)PDF 1.81 M
    应用笔记
    文档备注
    AN-1415: ADE9078 Low Power Mode for No Voltage Detection (Rev. 0)PDF 120.58 K
    用户手册
    文档备注
    UG-953: Evaluating the ADE9078 High Performance, Polyphase Energy Metering Analog Front End (AFE) (Rev. 0)PDF 2.71 M
    订购信息
    产品型号封装包装数量温度范围美金报价 100-499美金报价 1000+RoHS
    ADE9078ACPZ 量产40 ld LFCSP (6x6mm w/4.6mm pad) OTH 490-40 至 85至6.285.85Y
    ADE9078ACPZ-RL 量产40 ld LFCSP (6x6mm w/4.6mm pad) REEL 2500-40 至 85至05.85Y
    评估板
    产品型号描述美金报价RoHS
    EVAL-ADE9078EBZEvaluation Board390Y
    EVAL-SDP-CB1ZController Board99Y
    ADE9078: High Performance, Polyphase Energy Metering AFE Data Sheet (Rev. 0) ade9078
    ADE9078 Calibration Tool ade9078
    AN-1415: ADE9078 Low Power Mode for No Voltage Detection (Rev. 0) ade9078
    UG-953: Evaluating the ADE9078 High Performance, Polyphase Energy Metering Analog Front End (AFE) (Rev. 0) ade9078