Parametric | ESD112-B1-02ELS |
---|
VRWM
min
max | -5.3V
5.3V |
---|
CL
(max) | 0.23pF
(0.4pF) |
---|
VESD
min
max | -20.0kV
20.0kV |
---|
Rdyn
(reverse) | 1.0Ω |
---|
Rdyn
(forward) | 1.0Ω |
---|
Vcl typ. reverse
(TLP 16A) | 29V |
---|
Vcl typ. reverse
(TLP 30A) | 38V |
---|
Vcl typ. forward
(TLP 16A) | 29V |
---|
Vcl typ. forward
(TLP 30A) | 38V |
---|
IR
max | 50.0µA |
---|
IEFT | 40A |
---|
Isurge | 3A |
---|
Protected Lines | 1 |
---|
Sales Product Name | ESD112-B1-02ELS |
---|
OPN | ESD112B102ELSE6327XTSA1 |
---|
Product Status | active |
---|
Package Name | PG-TSSLP-2 |
---|
Completely lead free | yes |
---|
Halogen free | yes |
---|
RoHS compliant | yes |
---|
Packing Size | 15000 |
---|
Packing Type | TAPE & REEL |
---|
Moisture Level | 1 |
---|
| Summary of Features:- ESD / transient protection of RF signal lines according to: – IEC61000-4-2 (ESD): ±20 kV (air/contact) – IEC61000-4-4 (EFT): 40 A (5/50 ns) – IEC61000-4-5 (surge): 3 A (8/20 μs)
- Maximum working voltage: VRWM ±5.3 V
- Extremely low capacitance: CL = 0.2 pF (typical)
- Low clamping voltage: VCL = 29 V at IPP = 16 A (typical)
- Very low reverse current IR < 1 nA typ.
- Very small form factor down to 0.62 x 0.32 x 0.31 mm3
- Pb-free (RoHS compliant) and halogen free package
Target Applications:- ESD protection of sensitive RF signal lines, Bluetooth Class 2, Automated Meter Reading
- RF antenna protection, frontend module, GPS, mobile TV, FM radio, UWB
|