Parametric | ESD24VS2U |
---|
VRWM
max | 24.0V |
---|
CL
(max) | 48.0pF
(52.0pF) |
---|
VESD
max | 30.0kV |
---|
VESD
(IEC61000-4-2 contact)
min | 30.0kV |
---|
Rdyn
(forward) | 0.11Ω |
---|
Rdyn
(reverse) | 0.22Ω |
---|
Vcl typ. reverse
(TLP 16A) | 37V |
---|
Vcl typ. reverse
(TLP 30A) | 40V |
---|
Vcl typ. forward
(TLP 16A) | 2.6V |
---|
Vcl typ. forward
(TLP 30A) | 4.2V |
---|
IR
max | 10.0µA |
---|
IR
(@VR=24V) | 1.0nA |
---|
IR | 1.0nA |
---|
IEFT | 80A |
---|
Isurge | 5A |
---|
Protected Lines | 2 |
---|
Sales Product Name | ESD24VS2U |
---|
OPN | ESD24VS2UE6327HTSA1 |
---|
Product Status | active and preferred |
---|
Package Name | PG-SOT23-3 |
---|
Completely lead free | yes |
---|
Halogen free | no |
---|
RoHS compliant | yes |
---|
Packing Size | 3000 |
---|
Packing Type | TAPE & REEL |
---|
Moisture Level | 1 |
---|
| |
---|
OPN | |
---|
Product Status | active and preferred |
---|
Package Name | PG-SOT23-3 |
---|
Completely lead free | no |
---|
Halogen free | yes |
---|
RoHS compliant | yes |
---|
Packing Size | 3000 |
---|
Packing Type | TAPE & REEL |
---|
Moisture Level | |
---|
| Summary of Features:- ESD / transient protection of CAN/LIN bus networks power supply lines according to: IEC61000-4-2 (ESD): ±30kV (air / contact) ,IEC61000-4-4 (EFT): 80 A (5/50 ns) ,IEC61000-4-5 (surge): 5 A (8/20μs) ,ISO7637-2: Pulse 1 (max. 50 V), Pulse 2 (max. 125 V), Pulse 3a, b (max.800 V)
- Max. working voltage: 24 V
- Low capacitance: 24 pF typ.
- Low clamping voltage: < 41 V
- Extremely low reverse current: < 1 nA typ.
- Pb-free (RoHS compliant) package
Target Applications:- Low and High-Speed CAN
- Fault Tolerant CAN
- Industrial control networks
- 12/24 V DC power supply lines
|