ADE7758 Poly Phase Multifunction Energy Metering IC with Per Phase Information

The ADE7758 has a waveform sample register that allows access to the ADC outputs. The part also incorporates a detection circuit for short duration low or high voltage variations. The voltage threshold levels and the duration (number of half-line cycles) of the variation are user programmable. A zero-crossing detection is synchronized with the zero-crossing point of the line voltage of any of the three phases. This information can be used to measure the period of any one of the three voltage inputs. The zero-crossing detection is used inside the chip for the line cycle energy accumulation mode. This mode permits faster and more accurate calibration by synchronizing the energy accumulation with an integer number of line cycles. Data is read from the ADE7758 via the SPI serial interface. The interrupt request output (IRQ) is an open-drain, active low logic output. The IRQ output goes active low when one or more interrupt events have occurred in the ADE7758. A status register indicates the nature of the interrupt. The ADE7758 is available in a 24-lead SOIC package.

The ADE7758 is a high accuracy, 3-phase electrical energy measurement IC with a serial interface and two pulse outputs. The ADE7758 incorporates second-order Σ-Δ ADCs, a digital integrator, reference circuitry, a temperature sensor, and all the signal processing required to perform active, reactive, and apparent energy measurement and rms calculations.

The ADE7758 is suitable to measure active, reactive, and apparent energy in various 3-phase configurations, such as WYE or DELTA services, with both three and four wires. The ADE7758 provides system calibration features for each phase, that is, rms offset correction, phase calibration, and power calibration. The APCF logic output gives active power information, and the VARCF logic output provides instantaneous reactive or apparent power information.

The ADE7758 has a waveform sample register that allows access to the ADC outputs. The part also incorporates a detection circuit for short duration low or high voltage variations. The voltage threshold levels and the duration (number of half-line cycles) of the variation are user programmable. A zero-crossing detection is synchronized with the zero-crossing point of the line voltage of any of the three phases. This information can be used to measure the period of any one of the three voltage inputs. The zero-crossing detection is used inside the chip for the line cycle energy accumulation mode. This mode permits faster and more accurate calibration by synchronizing the energy accumulation with an integer number of line cycles.

Data is read from the ADE7758 via the SPI serial interface. The interrupt request output (IRQ) is an open-drain, active low logic output. The IRQ output goes active low when one or more interrupt events have occurred in the ADE7758. A status register indicates the nature of the interrupt. The ADE7758 is available in a 24-lead SOIC package.

Features and Benefits
  • Highly accurate; supports IEC 60687, IEC 61036, IEC 61268, IEC 62053-21, IEC 62053-22, and IEC 62053-23
  • Compatible with 3-phase/3-wire, 3-phase/4-wire, and other 3-phase services
  • Less than 0.1% active energy error over a dynamic range of 1000 to 1 at 25°C
  • Supplies active/reactive/apparent energy, voltage rms, current rms, and sampled waveform data
  • Two pulse outputs, one for active power and the other selectable between reactive and apparent power with programmable frequency
  • Digital power, phase, and rms offset calibration
  • On-chip, user-programmable thresholds for line voltage SAG and overvoltage detections
  • See Data Sheet for Additional Information
Analog to Digital Converters
Software & Systems Requirements
Data Sheets
Documentnote
ADE7758: Poly Phase Multifunction Energy Metering IC with Per Phase Information Data Sheet (Rev. E)PDF 1105 kB
Application Notes
Documentnote
AN-1334: Impact of Adding a Neutral Attenuation Network in a 3P4W Wye System (Rev. 0)PDF 316.46 K
AN-750: ADE7758 Phase Dropout Detection for VAR Calculation (Rev. 0)PDF 79 kB
Frequently Asked Questions
Documentnote
Order Information
Part NumberPackagePacking QtyTemp RangePrice 100-499Price 1000+RoHS
ADE7758ARWZ Production24 ld SOIC - WideOTH 31-40 to 85C6.496.49Y
ADE7758ARWZRL Production24 ld SOIC - WideREEL 1000-40 to 85C06.49Y
Reference Materials
ADE7758: Poly Phase Multifunction Energy Metering IC with Per Phase Information Data Sheet (Rev. E) ade7758
ADE7758 Evaluation Board Software ade7758
AN-1334:在3P4WY形系统中添加中心线线衰减网络的影响 (Rev. 0) ade7754
AN-1334: Impact of Adding a Neutral Attenuation Network in a 3P4W Wye System (Rev. 0) ade7754
AN-750: ADE7758的相丢失检测与VAR计算 (Rev. 0) ade7758
AN-750: ADE7758 Phase Dropout Detection for VAR Calculation (Rev. 0) ade7758
IC Technology and Failure Mechanisms - Understanding Reliability Standards... ade7755
Reactive Energy Measurement Made Simple ade7753
Measuring Harmonic Energy with a Solid State Energy Meter ade7755