ADE7868 Poly Phase Multifunction Energy Metering IC with Tamper Detection and Low Power Mode
The ADE7868 is a high accuracy, 3-phase electrical energy
measurement IC with serial interfaces and three flexible pulse
outputs. The ADE7868 incorporates second-order Σ-Δ ADCs, a
digital integrator, reference circuitry, and all the signal
processing required to perform total (fundamental and
harmonic) active, reactive and apparent energy measurement,
and rms calculations. A fixed function digital signal processor
(DSP) executes this signal processing.
The ADE7868 is suitable to measure active, reactive, and
apparent energy in various 3-phase configurations, such as
WYE or DELTA services, with both three and four wires. The
ADE7868 provides system calibration features for each phase,
that is, rms offset correction, phase calibration, and gain
calibration. The CF1, CF2 and CF3 logic outputs provide a wide
choice of power information: total active/reactive/apparent
power or sum of current rms values.
The ADE7868 has waveform sample registers that allow access
to all ADC outputs. The device also incorporates power quality
measurements such as short duration low or high voltage
detections, short duration high current variations, line voltage
period measurement and angles between phase voltages and
currents. Two serial interfaces can be used to communicate with
the ADE7868: SPI or I2C while a dedicated high speed interface,
HSDC (High Speed Data Capture) port, can be used in
conjunction with I2C to provide access to the ADC outputs and
real time power information. The ADE7868 has also two
interrupt request pins, IRQ0 and IRQ1, to indicate that an
enabled interrupt event has occurred.
Three specially designed low power modes ensure the
continuity of the energy accumulation when the ADE7868 is in
tampering situation.
The ADE7868 is available in 40-lead LFCSP lead free package.
Features and Benefits- Highly accurate; supports EN 50470-1, EN 50470-3, IEC 62053-21, IEC 62053-22 and IEC 62053-23
- Compatible with 3-phase, 3 or 4 wire (delta or wye) and other 3-phase services
- Supplies total (fundamental and harmonic) active/reactive/ apparent energy on each phase and on the overall system
- Less than 0.1% error in active and reactive energy over a dynamic range of 1000 to 1 at 25°C
- Less than 0.2% error in active and reactive energy over a dynamic range of 3000 to 1 at 25°C
- Supports current transformer and di/dt current sensors
- Dedicated ADC channel for the neutral current input
- Less than 0.1% error in voltage and current rms over a dynamic range of 1000 to 1 at 25°C
- Supplies sampled waveform data on all 3 phases and neutral current
- See data sheet for additional features
| |
Data Sheets
Application Notes
User Guides
Product Highlight
Frequently Asked Questions
Order Information
Part Number | Package | Packing Qty | Temp Range | Price 100-499 | Price 1000+ | RoHS |
---|
ADE7868ACPZ Production | 40 ld LFCSP (6x6mm w_4.3mm EP) | OTH 490 | -40 to 85C | 4.89 | 4.89 | Y |
ADE7868ACPZ-RL Production | 40 ld LFCSP (6x6mm w_4.3mm EP) | REEL 2500 | -40 to 85C | 0 | 4.89 | Y |
Evaluation Boards
Part Number | Description | Price | RoHS |
---|
EVAL-ADE7878EBZ | Evaluation Board | 390 | Y |
Reference Materials