ADG5462F User Defined Fault Protection and Detection,10 Ω Ron, Quad Channel Protector

The ADG5462F contains four channels that are overvoltage protected. The channel protector is placed in series with the signal path and protects sensitive components from overvoltage faults in that path. The channel protector prevents overvoltages when powered and unpowered, and it is ideal for use in applications where correct power supply sequencing cannot always be guaranteed. The primary supply voltages define the on-resistance profile, while the secondary supply voltages define the voltage level at which the overvoltage protection engages. When no power supplies are present, the channel remains in the off condition, and the channel inputs are high impedance. Under normal operating conditions, if the analog input signal levels on any Sx pin exceed positive fault voltage (POSFV) or negative fault voltage (NEGFV) by a threshold voltage (VT), the channel turns off and that Sx pin becomes high impedance. If the DR pin is driven low, the drain pin (Dx) is pulled to the secondary supply voltage that was exceeded. The output profile for each DR voltage level is shown in Figure 1. Input signal levels up to −55 V or +55 V relative to ground are blocked in both the powered and unpowered conditions. The low on-resistance of these switches, combined with the on-resistance flatness over a significant portion of the signal range make them an ideal solution for data acquisition and instrumentation applications where excellent linearity and low distortion are critical. Product Highlights Source pins are protected against voltages greater than the secondary supply rails (POSFV and NEGFV), up to −55 V and +55 V. In an unpowered state, source pins (Sx) are protected against voltages from −55 V to +55 V. Overvoltage detection with digital output indicates operating state of channel. Trench isolation guards against latch-up. Optimized for low on-resistance and on-resistance flatness. The ADG5462F operates from a dual power supply range of ±5 V to ±22 V or a single power supply range of 8 V to 44 V. Applications

Features and Benefits
  • User defined secondary supplies set overvoltage level
  • Overvoltage protection up to −55 V and +55 V
  • Power-off protection up to −55 V and +55 V
  • Overvoltage detection on source pins
  • Minimum secondary supply level: 4.5 V single-supply
  • Interrupt flag indicates fault status
  • Low on resistance: 10 Ω typical
  • On-resistance flatness: 0.5 Ω maximum
  • 4 kV human body model (HBM) ESD rating
  • Latch-up immune under any circumstance
  • VSS to VDD analog signal range
  • ±5 V to ±22 V dual supply operation
  • 8 V to 44 V single-supply operation
  • Fully specified at ±15 V, ±20 V, +12 V, and +36 V
  • Switches & Multiplexers
    Data Sheets
    Documentnote
    ADG5462F: User Defined Fault Protection and Detection,10 Ω Ron, Quad Channel Protector Data Sheet (Rev. B)PDF 503.39 K
    Application Notes
    Documentnote
    AN-1380: Generating Secondary Fault Supplies for Fault Protected SwitchesPDF 184.23 K
    User Guides
    Documentnote
    UG-908: Evaluating the ADG5462F User Defined Fault Protection and Detection, 10 Ω RON, Quad Channel Protector (Rev. 0)PDF 398.16 K
    Order Information
    Part NumberPackagePacking QtyTemp RangePrice 100-499Price 1000+RoHS
    ADG5462FBCPZ-RL7 Production16 ld LFCSP 4x4 REEL 1500-40 to 125C03.86Y
    ADG5462FBRUZ Production16 ld TSSOPOTH 96-40 to 125C4.713.86Y
    ADG5462FBRUZ-RL7 Production16 ld TSSOPREEL 1000-40 to 125C03.86Y
    Evaluation Boards
    Part NumberDescriptionPriceRoHS
    EVAL-ADG5462FEBZEvaluation Board50Y
    Reference Materials
    ADG5462F:用户自定义故障保护和检测、 10  RON、四通道保护器 (Rev. B) adg5462f
    ADG5462F: User Defined Fault Protection and Detection,10 Ω Ron, Quad Channel Protector Data Sheet (Rev. B) adg5462f
    AN-1380:产生故障保护开关的副故障电源 adg5462f
    AN-1380: Generating Secondary Fault Supplies for Fault Protected Switches adg5462f
    UG-908: Evaluating the ADG5462F User Defined Fault Protection and Detection, 10 Ω RON, Quad Channel Protector (Rev. 0) adg5462f
    用过压故障保护模拟开关代替分立保护器件 adg5404