ADM3054 5 kV rms Signal Isolated High Speed CAN Transceiver with Bus Protection

The ADM3054 is a 5 kV rms signal isolated controller area network (CAN) physical layer transceiver. The ADM3054 complies with the ISO 11898 standard.

The device employs Analog Devices, Inc., iCoupler® technology to combine a 3-channel isolator and a CAN transceiver into a single package. The logic side of the device is powered with a single 3.3 V or 5 V supply on VDD1 and the bus side uses a single 5 V supply on VDD2 only. Loss of power on the bus side (VDD2) can be detected by an integrated VDD2SENSE signal.

The ADM3054 creates an isolated interface between the CAN protocol controller and the physical layer bus. It is capable of running at data rates of up to 1 Mbps.

The device has integrated protection on the bus pins, CANH, and CANL against shorts to power/ground in 24 V systems.

The device has current-limiting and thermal shutdown features to protect against output short circuits and situations where the bus might be shorted to ground or power terminals. The part is fully specified over the industrial temperature range and is available in a 16-lead, wide-body SOIC package.

Applications
  • CAN data buses
  • Industrial field networks
Features and Benefits
  • 5 kV rms signal isolated CAN transceiver
  • 5 V or 3.3 V operation on VDD1
  • 5 V operation on VDD2
  • VDD2SENSE to detect loss of power on VDD2
  • Complies with ISO 11898 standard
  • High speed data rates of up to 1 Mbps
  • Short-circuit protection on CANH and CANL against shorts to power/ground in 24 V systems
  • Unpowered nodes do not disturb the bus
  • Connect 110 or more nodes on the bus
  • Thermal shutdown protection
  • High common-mode transient immunity: >25 kV/μs
  • See datasheet for additional features
Interface & Isolation
IBIS Models
Data Sheets
Documentnote
ADM3054: 5 kV rms Signal Isolated High Speed CAN Transceiver with Bus Protection Data Sheet (Rev. B)PDF 353 kB
Application Notes
Documentnote
AN-1179: Junction Temperature Calculation for Analog Devices RS-485/RS-422, CAN, and LVDS/M-LVDS Transceivers (Rev. A)PDF 156.87 K
AN-1123: Controller Area Network (CAN) Implementation Guide (Rev. 0)PDF 204 kB
AN-1176: Component Footprints and Symbols in the Binary .Bxl File Format (Rev. 0)PDF 671 kB
User Guides
Documentnote
UG-358: Evaluation Board for the ADM3054 5 kV rms Signal Isolated High Speed CAN Transceiver with Bus ProtectionPDF 185 kB
Order Information
Part NumberPackagePacking QtyTemp RangePrice 100-499Price 1000+RoHS
ADM3054BRWZ Production16 ld SOIC - WideOTH 47-40 to 125C2.472.1Y
ADM3054BRWZ-RL7 Production16 ld SOIC - WideREEL 400-40 to 125C02.1Y
ADM3054WBRWZ-RL7 Production16 ld SOIC - WideREEL 400-40 to 125C02.42Y
Evaluation Boards
Part NumberDescriptionPriceRoHS
EVAL-ADM3054EBZEvaluation Board75Y
ADM3054: 5 kV rms Signal Isolated High Speed CAN Transceiver with Bus Protection Data Sheet (Rev. B) adm3054
ADM3054: 5 kV rms信号隔离高速CAN收发器,提供系统总线保护数据手册 (Rev. A) adm3054
ADM3054 IBIS Model adm3054
AN-1179: Junction Temperature Calculation for Analog Devices RS-485/RS-422, CAN, and LVDS/M-LVDS Transceivers (Rev. A) adn4670
AN-1123: Controller Area Network (CAN) Implementation Guide (Rev. 0) adm3052
AN-1176:二进制.Bxl文件格式的元件尺寸和符号 (Rev. 0) adn4670
AN-1176: Component Footprints and Symbols in the Binary .Bxl File Format (Rev. 0) adn4670
AN-1123: 控制器局域网(CAN)实施指南 (Rev. 0) adm3052
UG-358: Evaluation Board for the ADM3054 5 kV rms Signal Isolated High Speed CAN Transceiver with Bus Protection adm3054