ADP1047 Digital Power Factor Correction Controller with accurate AC Power Metering
The ADP1047/ADP1048 provide accurate rms measurement of input voltage, current, and power. This information can be reported to the microcontroller of the power supply via the
PMBus interface.
Applications
AC/DC power supplies for applications
Computing Server & Storage
Network and communication infrastructure
Industrial and Medical
The ADP1047/ADP1048 are digital power factor correction (PFC) controllers that provide accurate input power metering capability and inrush current control for ac/dc systems. The ADP1047 is designed for single phase PFC applications; the ADP1048 is designed especially for interleaved and bridgeless PFC applications.
The digital PFC function is based on a conventional boost PFC with multiplication of the output voltage feedback combined with the input current and voltage to provide optimum harmonic correction and power factor for ac/dc systems. All signals are converted into the digital domain to provide maximum flexibility; all key parameters can be reported and adjusted via the PMBus™ interface. The ADP1047/ADP1048 allow users to optimize system performance, maximize efficiency across the load range, and reduce design time to market.
The ADP1047/ADP1048 provide accurate rms measurement of input voltage, current, and power. This information can be reported to the microcontroller of the power supply via the
PMBus interface.
Applications
- AC/DC power supplies for applications
Computing Server & Storage
Network and communication infrastructure
Industrial and Medical
Features and Benefits- Flexible digital power factor correction (PFC) controller
- Single phase operation (ADP1047); interleaved and bridgeless operation (ADP1048)
- True rms ac power metering
- Enhanced dynamic response
- Optimized light load efficiency performance
Output voltage adjustment
Frequency reduction - Inrush current control
- Switching frequency spread spectrum for improved EMI
- External frequency synchronization
- PMBus compliant
Programmable ac line fault detection and protection
Programmable output fault detection and protection - Extensive fault protection for high reliability systems
- Frequency range from 30 kHz to 400 kHz
- 8 kB EEPROM
- Programming via easy-to-use graphical user interface (GUI)
| Building TechnologySoftware & Systems Requirements |
Data Sheets
Application Notes
Evaluation Kit Manuals
Order Information
Part Number | Package | Packing Qty | Temp Range | Price 100-499 | Price 1000+ | RoHS |
---|
ADP1047ARQZ-R7 Production | 24 ld QSOP | REEL 1000 | -40 to 85C | 0 | 3 | Y |
Evaluation Boards
Part Number | Description | Price | RoHS |
---|
ADP1047-300-EVALZ | 300W Evaluation Board | 500 | Y |
ADP1047DC1-EVALZ | ADP1047 Daughter Card | 200 | Y |
ADP-I2C-USB-Z | USB to I2C Connector | 250 | Y |
Reference Materials