DataSheet:Download SB6100 Datasheet
The Industrial Shock-Block is available with adjustable protection settings as an EGFPD. The EGFPD models (hardware revision 1) can be set to trip at 6mA, and 10 to 100mA in increments of 10mA. This helps reduce nuisance tripping in systems with leakage current higher than the standard 6 mA required by UL 943 Class A GFCI (GFCI devices are not allowed to have an adjustable trip level).
All ordering options include CSA certification.
Catalog # | Conformally Coated PWB | Dimensions | Frequency (Hz) | Full Load Current (A) | GF Trip Level (A) | NEMA Rating | RelayContacts | RelayContactOperatingMode | System Type | SupplyVoltage(VAC) |
---|---|---|---|---|---|---|---|---|---|---|
SB6100-000-0 | Standard | 455.0 x 340.7 mmx 174.9 mm | 60 | 100 | 20 mA | One Form A (N.O.) | Fail-safe | 208 | ||
SB6100-001-0 | Standard | 453.8x 406.2 mmx 223.3 mm | 60 | 100 | 20 mA | NEMA 4X | One Form A (N.O.) | Fail-safe | Grounded | 208 |
SB6100-010-0 | Standard | 455.0 x 340.7 mmx 174.9 mm | 60 | 100 | 6, 10-100 mA in increments of 10 mA | One Form A (N.O.) | Fail-safe | Grounded | 208 | |
SB6100-011-0 | Standard | 453.8x 406.2 mmx 223.3 mm | 60 | 100 | 6, 10-100 mA in increments of 10 mA | NEMA 4X | One Form A (N.O.) | Fail-safe | Grounded | 208 |
SB6100-100-0 | Standard | 455.0 x 340.7 mmx 174.9 mm | 60 | 100 | 20 mA | One Form A (N.O.) | Fail-safe | Grounded | 240 | |
SB6100-101-0 | Standard | 453.8x 406.2 mmx 223.3 mm | 60 | 100 | 20 mA | NEMA 4X | One Form A (N.O.) | Fail-safe | Grounded | 240 |
SB6100-110-0 | Standard | 455.0 x 340.7 mmx 174.9 mm | 60 | 100 | 6, 10-100 mA in increments of 10 mA | One Form A (N.O.) | Fail-safe | Grounded | 240 | |
SB6100-111-0 | Standard | 453.8x 406.2 mmx 223.3 mm | 60 | 100 | 6, 10-100 mA in increments of 10 mA | NEMA 4X | One Form A (N.O.) | Fail-safe | Grounded | 240 |
SB6100-200-0 | Standard | 455.0 x 340.7 mmx 174.9 mm | 60 | 100 | 20 mA | One Form A (N.O.) | Fail-safe | Grounded | 480 | |
SB6100-201-0 | Standard | 453.8x 406.2 mmx 223.3 mm | 60 | 100 | 20 mA | NEMA 4X | One Form A (N.O.) | Fail-safe | Grounded | 480 |
SB6100-210-0 | Standard | 455.0 x 340.7 mmx 174.9 mm | 60 | 100 | 6, 10-100 mA in increments of 10 mA | One Form A (N.O.) | Fail-safe | Grounded | 480 | |
SB6100-211-0 | Standard | 453.8x 406.2 mmx 223.3 mm | 60 | 100 | 6, 10-100 mA in increments of 10 mA | NEMA 4X | One Form A (N.O.) | Fail-safe | Grounded | 480 |
SB6100-300-0 | Standard | 455.0 x 340.7 mmx 174.9 mm | 60 | 100 | 20 mA | One Form A (N.O.) | Fail-safe | Grounded | 600 | |
SB6100-301-0 | Standard | 453.8x 406.2 mmx 223.3 mm | 60 | 100 | 20 mA | NEMA 4X | One Form A (N.O.) | Fail-safe | Grounded | 600 |
SB6100-310-0 | Standard | 455.0 x 340.7 mmx 174.9 mm | 60 | 100 | 6, 10-100 mA in increments of 10 mA | One Form A (N.O.) | Fail-safe | Grounded | 600 | |
SB6100-311-0 | Standard | 453.8x 406.2 mmx 223.3 mm | 60 | 100 | 6, 10-100 mA in increments of 10 mA | NEMA 4X | One Form A (N.O.) | Fail-safe | Grounded | 600 |