NX5P3090UK:USB PD and type C current-limited power switch

The NX5P3090 is a precision adjustable current-limited power switch for USB PD application. The device includes under voltage lockout, over-temperature protection, and reverse current protection circuits to automatically isolate the switch terminals when a fault condition occurs. The 29V tolerance on VBUS pin ensures the device is able to work on a USB PD port; a current limit input (ILIM) pin defines the over-current limit threshold; an open-drain fault output (FAULT) indicates when a fault condition has occurred.

The over-current limit threshold can be programmed from 400 mA to 3.3 A, using an external resistor between the ILIM pin and GND pin. In the over current condition, the device will clamp the output current to the value set by ILIM and keep the switch on while assert the FAULT flag. To minimize current surges during turn on and turn off, the device has built in soft start which controls the power switch rise and fall time.

Surge protection has been integrated in the device to enhance system robustness. The enable input includes integrated logic level translation making the device compatible with lower voltage processors and controllers.

NX5P3090 is offered in a 12 bump 1.35 × 1.65 mm, 0.4 mm pitch WLCSP package.

特性和优势
    • VINT supply voltage range from 2.5 V to 5.5 V
    • 29 V Tolerance on VBUS and EN Pin
    • ISW 3.3 A maximum load current
    • Adjustable current limit from 400 mA to 3.3 A
    • Clamped current output in over-current condition
    • Very low ON resistance: 30 mΩ (typical)
    • VBUS quick discharge after EN disable with time out control
    • Active High EN pin with internal pull down resistor
    • All time Reverse Current Protection
    • Over Temperature Protection
    • Surge protection: IEC61000-4-5 exceeds ±100 V on VBUS
    • ESD protection:
      • IEC61000-4-2 contact discharge exceeds 8 kV on VBUS
      • HBM ANSI/ESDA/JEDEC JS-001 Class 2 exceeds 2 kV
      • CDM AEC standard Q100-01 (JESD22-C101E)
    • IEC61000-4-2 contact discharge exceeds 8 kV on VBUS
    • HBM ANSI/ESDA/JEDEC JS-001 Class 2 exceeds 2 kV
    • CDM AEC standard Q100-01 (JESD22-C101E)
    • Specified from -40 °C to +85 °C ambient temperature
应用
    • USB PD and Type C port/hubs
    • Tablet and Smart phone
    • Notebook and Ultrabook
产品图片
关键参数
型号Product status
NX5P3090UKDevelopment
封装与包装
型号封装Outline versionReflow-/Wave soldering包装产品状态标示可订购的器件编号, (订购码 (12NC))
NX5P3090UK()开发中Standard MarkingNX5P3090UKZ( 9353 057 02012 )
无铅环保信息
型号可订购的器件编号RoHS / RHF无铅转换日期潮湿敏感度等级MSL LF
NX5P3090UKNX5P3090UKZAlways Pb-free11
订购信息
型号订购码 (12NC)可订购的器件编号
NX5P3090UK9353 057 02012NX5P3090UKZ