Part Number | Category | Number of Circuits | IFT (Max) (mA) | RON (Max) (Ω) | ION (Max) (A) | VOFF (Max) (V) | COFF (Typ.) (pF) | Topr (Min) (degC) | Topr (Max) (degC) | BVS (Min) (Vrms) | Safety Standard (UL) | Safety Standard (cUL) | Safety Standard (VDE-TÜV) | Safety Standard (SEMKO) | Safety Standard (BSI) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TLP170A | 1a | 1 | 1 | 2 | 0.4 | 60 | 130 | -40 | 85 | 1500 | Approved | Approved | |||
TLP170D | 1a | 1 | 1 | 0.2 | 200 | 90 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP170G | 1a | 1 | 1 | 0.1 | 350 | 35 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP170J | 1a | 1 | 1 | 0.09 | 600 | 75 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP171A | 1a | 1 | 0.1 | 0.4 | 60 | 130 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP171D | 1a | 1 | 0.1 | 0.2 | 200 | 90 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP171GA | 1a | 1 | 0.1 | 0.1 | 400 | 35 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP171J | 1a | 1 | 0.1 | 0.07 | 600 | 75 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP172AM | 1a | 1 | 3 | 0.4 | 60 | 130 | -40 | 110 | 3750 | ||||||
TLP172A | 1a | 1 | 3 | 0.4 | 60 | 130 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP172GM | 1a | 1 | 3 | 0.11 | 350 | 30 | -40 | 110 | 3750 | ||||||
TLP172G | 1a | 1 | 3 | 0.11 | 350 | 30 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP174GA | 1a | 1 | 3 | 0.12 | 400 | 70 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP174G | 1a | 1 | 3 | 0.12 | 350 | 70 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP175A | 1a | 1 | 1 | 0.1 | 60 | 10 | -40 | 85 | 3750 | Approved | Approved | ||||
TLP176A | 1a | 1 | 3 | 0.4 | 60 | 130 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP176D | 1a | 1 | 3 | 0.2 | 200 | 100 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP176GA | 1a | 1 | 3 | 0.12 | 400 | 70 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP176G | 1a | 1 | 3 | 0.12 | 350 | 40 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP179D | 1a | 1 | 3 | 0.05 | 200 | 15 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP192A | 1a | 1 | 3 | 0.4 | 60 | 130 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP192G | 1a | 1 | 3 | 0.11 | 350 | 30 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP197A | 1a | 1 | 3 | 0.4 | 60 | 130 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP197GA | 1a | 1 | 3 | 0.12 | 400 | 70 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP197G | 1a | 1 | 3 | 0.12 | 350 | 40 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP199D | 1a | 1 | 3 | 0.05 | 200 | 15 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP200D | 2a | 2 | 3 | 0.2 | 200 | 100 | -40 | 85 | 1500 | Approved | |||||
TLP202A | 2a | 2 | 3 | 0.4 | 60 | 130 | -40 | 85 | 1500 | Approved | |||||
TLP202G | 1a | 2 | 3 | 0.11 | 350 | 30 | -40 | 85 | 1500 | Approved | |||||
TLP206A | 2a | 2 | 3 | 0.4 | 60 | 140 | -40 | 85 | 1500 | Approved | |||||
TLP206GA | 2a | 2 | 3 | 0.12 | 400 | 70 | -40 | 85 | 1500 | Approved | |||||
TLP206G | 2a | 2 | 3 | 0.12 | 350 | 40 | -40 | 85 | 1500 | Approved | |||||
TLP220AF | 1a | 1 | 2 | 0.5 | 60 | 130 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP220A | 1 | 2 | 0.5 | 60 | 130 | -40 | 85 | 5000 | Approved | Approved | |||||
TLP220DF | 1a | 1 | 2 | 0.25 | 200 | 90 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP220D | 1a | 1 | 2 | 0.25 | 200 | 90 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP220GAF | 1a | 1 | 2 | 0.12 | 400 | 80 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP220GA | 1a | 1 | 2 | 0.12 | 400 | 80 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP220GF | 1a | 1 | 2 | 0.1 | 350 | 30 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP220G | 1a | 1 | 2 | 0.1 | 350 | 30 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP220JF | 1a | 1 | 2 | 0.09 | 600 | 75 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP220J | 1a | 1 | 2 | 0.09 | 600 | 75 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP222A-2 | 2a | 2 | 3 | 0.5 | 60 | 130 | -40 | 85 | 2500 | Approved | Approved | ||||
TLP222A | 1a | 1 | 3 | 0.5 | 60 | 130 | -40 | 85 | 2500 | Approved | Approved | ||||
TLP222D | 1a | 1 | 3 | 0.3 | 200 | 100 | -40 | 85 | 2500 | Approved | Approved | ||||
TLP222G-2 | 2a | 2 | 3 | 0.12 | 350 | 30 | -40 | 85 | 2500 | Approved | Approved | ||||
TLP222G | 1a | 1 | 3 | 0.12 | 350 | 30 | -40 | 85 | 2500 | Approved | Approved | ||||
TLP224G-2 | 2a | 2 | 3 | 0.12 | 350 | 40 | -40 | 85 | 2500 | Approved | Approved | ||||
TLP224GA-2 | 2a | 2 | 3 | 0.12 | 400 | 2500 | Approved | Approved | |||||||
TLP224GA | 1a | 1 | 3 | 0.12 | 400 | 2500 | Approved | Approved | |||||||
TLP224G | 1a | 1 | 3 | 0.12 | 350 | 40 | -40 | 85 | 2500 | Approved | Approved | ||||
TLP225A | 1a | 1 | 5 | 0.5 | 60 | -20 | 85 | 2500 | Approved | Approved | |||||
TLP227A-2 | 2a | 2 | 3 | 0.5 | 60 | 130 | -40 | 85 | 2500 | Approved | Approved | ||||
TLP227A | 1a | 1 | 3 | 0.5 | 60 | 130 | -40 | 85 | 2500 | Approved | Approved | ||||
TLP227G-2 | 2a | 2 | 3 | 0.12 | 350 | 40 | -40 | 85 | 2500 | Approved | Approved | ||||
TLP227GA-2 | 2a | 2 | 3 | 0.12 | 400 | -40 | 85 | 2500 | Approved | Approved | |||||
TLP227GA | 1a | 1 | 3 | 0.12 | 400 | -40 | 85 | 2500 | Approved | Approved | |||||
TLP227G | 1a | 1 | 3 | 0.12 | 350 | 40 | -40 | 85 | 2500 | Approved | Approved | ||||
TLP228G-2 | 2a | 2 | 3 | 350 | 30 | -40 | 85 | 2500 | Approved | ||||||
TLP228G | 1a | 1 | 3 | 350 | 30 | -40 | 85 | 2500 | Approved | Approved | |||||
TLP240AF | 1a | 1 | 3 | 0.5 | 60 | 130 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP240A | 1 | 3 | 0.5 | 60 | 130 | -40 | 85 | 5000 | Approved | Approved | |||||
TLP240DF | 1a | 1 | 3 | 0.25 | 200 | 90 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP240D | 1a | 1 | 3 | 0.25 | 200 | 90 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP240GAF | 1a | 1 | 3 | 0.12 | 400 | 80 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP240GA | 1a | 1 | 3 | 0.12 | 400 | 80 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP240GF | 1a | 1 | 3 | 0.1 | 350 | 30 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP240G | 1a | 1 | 3 | 0.1 | 350 | 30 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP240JF | 1a | 1 | 3 | 0.09 | 600 | 75 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP240J | 1a | 1 | 3 | 0.09 | 600 | 75 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP241AF | 1 | 3 | 2.0 | 40 | 300 | -40 | 85 | 5000 | Approved | Approved | |||||
TLP241A | 1 | 3 | 2.0 | 40 | 300 | -40 | 85 | 5000 | Approved | Approved | |||||
TLP3100 | 1a | 1 | 3 | 2.5 | 20 | 1000 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP3102 | 1a | 1 | 3 | 2.5 | 40 | 1000 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP3103 | 1a | 1 | 3 | 2.3 | 60 | 1000 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP3105 | 1a | 1 | 3 | 1.4 | 100 | 1000 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP3106 | 1a | 1 | 3 | 4.0 | 30 | 1000 | -40 | 85 | 1500 | ||||||
TLP3107 | 1a | 1 | 3 | 3.3 | 60 | 1000 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP3109 | 1a | 1 | 3 | 2.0 | 100 | 500 | -40 | 85 | 1500 | ||||||
TLP3122 | 1a | 1 | 3 | 1 | 60 | 90 | -20 | 85 | 1500 | Approved | Approved | ||||
TLP3123 | 1a | 1 | 3 | 1 | 40 | 300 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP3125 | 1a | 1 | 3 | 0.2 | 400 | 410 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP3127 | 1a | 1 | 3.0 | 1.7 | 60 | 250 | -40 | 85 | 1500 | Approved | Approved | ||||
TLP3203 | 1a | 1 | 3 | 0.9 | 20 | 40 | -20 | 85 | 1500 | Approved | |||||
TLP3212 | 1a | 1 | 5 | 0.4 | 60 | 20 | -20 | 85 | 1500 | Approved | |||||
TLP3214 | 1a | 1 | 4 | 0.25 | 40 | 5 | -20 | 85 | 1500 | Approved | |||||
TLP3215 | 1a | 1 | 4 | 0.3 | 40 | 10 | -20 | 85 | 1500 | Approved | |||||
TLP3216 | 1a | 1 | 4 | 0.12 | 40 | 1 | -20 | 85 | 1500 | Approved | |||||
TLP3217 | 1a | 1 | 4 | 0.12 | 80 | 5 | -20 | 85 | 1500 | Approved | |||||
TLP3220 | 1a | 1 | 5 | 0.08 | 100 | 6 | -20 | 85 | 1500 | Approved | |||||
TLP3230 | 1a | 1 | 4 | 0.16 | 20 | 1 | -20 | 85 | 1500 | Approved | |||||
TLP3231 | 1a | 1 | 4 | 0.45 | 20 | 5 | -20 | 85 | 1500 | Approved | |||||
TLP3240 | 1a | 1 | 3 | 0.12 | 40 | 0.45 | -20 | 85 | 1500 | Approved | |||||
TLP3241 | 1a | 1 | 3 | 0.14 | 40 | 0.7 | -20 | 85 | 1500 | Approved | |||||
TLP3250 | 1a | 1 | 3 | 0.2 | 20 | 0.8 | -20 | 85 | 1500 | Approved | |||||
TLP3275 | 1a | 1 | 3 | 0.3 | 50 | 12 | -20 | 85 | 1500 | Approved | |||||
TLP3303 | 1a | 1 | 3 | 0.9 | 20 | 40 | -40 | 85 | 500 | Approved | |||||
TLP3306 | 1a | 1 | 3 | 0.4 | 75 | 30 | -40 | 85 | 500 | Approved | |||||
TLP3312 | 1a | 1 | 3 | 0.4 | 60 | 20 | -40 | 85 | 500 | Approved | |||||
TLP3315 | 1a | 1 | 3 | 0.3 | 40 | 10 | -40 | 85 | 500 | Approved | |||||
Part Number | Category | Number of Circuits | IFT (Max) (mA) | RON (Max) (Ω) | ION (Max) (A) | VOFF (Max) (V) | COFF (Typ.) (pF) | Topr (Min) (degC) | Topr (Max) (degC) | BVS (Min) (Vrms) | Safety Standard (UL) | Safety Standard (cUL) | Safety Standard (VDE-TÜV) | Safety Standard (SEMKO) | Safety Standard (BSI) |
TLP3316 | 1a | 1 | 3 | 0.12 | 40 | 1 | -40 | 85 | 500 | Approved | |||||
TLP3317 | 1a | 1 | 3 | 0.12 | 80 | 5 | -40 | 85 | 500 | Approved | |||||
TLP3319 | 1a | 1 | 3 | 0.2 | 80 | 6.5 | -40 | 85 | 500 | Approved | |||||
TLP3320 | 1a | 1 | 3 | 0.1 | 100 | 6 | -40 | 85 | 500 | Approved | |||||
TLP3330 | 1a | 1 | 3 | 0.16 | 20 | 1 | -40 | 85 | 500 | Approved | |||||
TLP3340 | 1a | 1 | 3 | 0.12 | 40 | 0.45 | -40 | 85 | 500 | Approved | |||||
TLP3341 | 1a | 1 | 3 | 0.14 | 40 | 0.7 | -40 | 85 | 500 | Approved | |||||
TLP3342 | 1a | 1 | 3 | 0.1 | 40 | 0.3 | -40 | 85 | 500 | Approved | |||||
TLP3350 | 1a | 1 | 3 | 0.2 | 20 | 0.8 | -40 | 85 | 500 | Approved | |||||
TLP3351 | 1a | 1 | 3 | 0.12 | 60 | 0.7 | -40 | 85 | 500 | Approved | |||||
TLP3375 | 1a | 1 | 3 | 0.3 | 50 | 12 | -40 | 85 | 500 | Approved | |||||
TLP3403 | 1a | 1 | 3 | 1.0 | 20 | 40 | -40 | 85 | 300 | ||||||
TLP3412 | 1a | 1 | 3 | 0.4 | 60 | 20 | -40 | 85 | 300 | ||||||
TLP3417 | 1a | 1 | 3 | 0.12 | 80 | 5 | -40 | 85 | 300 | ||||||
TLP3419 | 1a | 1 | 300 | ||||||||||||
TLP3420 | 1a | 1 | 3 | 0.1 | 100 | 6 | -40 | 85 | 300 | ||||||
TLP3431 | 1a | 1 | 3 | 0.45 | 20 | 5 | -40 | 85 | 300 | ||||||
TLP3440 | 1a | 1 | 3 | 0.12 | 40 | 0.45 | -40 | 85 | 300 | ||||||
TLP3441 | 1a | 1 | 3 | 0.14 | 40 | 0.7 | -40 | 85 | 300 | ||||||
TLP3442 | 1a | 1 | 3 | 0.1 | 40 | 0.3 | -40 | 85 | 300 | ||||||
TLP3450 | 1a | 1 | 3 | 0.2 | 20 | 0.8 | -40 | 85 | 300 | ||||||
TLP3451 | 1a | 1 | 3 | 0.12 | 60 | 0.7 | -40 | 85 | 300 | ||||||
TLP3475 | 1a | 1 | 3 | 0.3 | 50 | 12 | -40 | 85 | 300 | ||||||
TLP3542 | 1a | 1 | 3 | 2.5 | 60 | 400 | -20 | 85 | 2500 | Approved | Approved | ||||
TLP3543 | 1a | 1 | 3 | 4 | 20 | 1000 | -40 | 85 | 2500 | Approved | Approved | ||||
TLP3544 | 1a | 1 | 3 | 3.5 | 40 | 1000 | -40 | 85 | 2500 | Approved | Approved | ||||
TLP3545 | 1a | 1 | 3 | 3.0 | 60 | 1000 | -40 | 85 | 2500 | Approved | Approved | ||||
TLP3546 | 1a | 1 | 3 | 2.0 | 100 | 1000 | -40 | 85 | 2500 | Approved | Approved | ||||
TLP3547 | 1a | 1 | 5 | 5.0 | 60 | 850 | -40 | 85 | 2500 | ||||||
TLP3548 | 1a | 1 | 1 | 0.4 | 400 | 410 | -40 | 85 | 2500 | ||||||
TLP3549 | 1a | 1 | 5 | 0.6 | 600 | 4300 | -40 | 85 | 2500 | ||||||
TLP3553 | 1a | 1 | 3 | 3 | 20 | 300 | -40 | 85 | 2500 | Approved | Approved | ||||
TLP3554 | 1a | 1 | 3 | 2.5 | 40 | 300 | -40 | 85 | 2500 | Approved | Approved | ||||
TLP3555 | 1a | 1 | 3 | 2.0 | 60 | 250 | -40 | 85 | 2500 | Approved | Approved | ||||
TLP3556 | 1a | 1 | 3 | 1.0 | 100 | 200 | -40 | 85 | 2500 | Approved | Approved | ||||
TLP4006G | 1a1b | 2 | 3 | 0.12 | 350 | 65 | -40 | 85 | 2500 | Approved | |||||
TLP4026G | 1a1b | 2 | 3 | 0.12 | 350 | 65 | -40 | 85 | 1500 | Approved | |||||
TLP4176G | 1b | 1 | 3 | 0.12 | 350 | 65 | -40 | 85 | 1500 | Approved | |||||
TLP4197G | 1b | 1 | 3 | 0.12 | 350 | 65 | -40 | 85 | 1500 | Approved | |||||
TLP4206G | 2b | 2 | 3 | 0.12 | 350 | 65 | -40 | 85 | 1500 | Approved | |||||
TLP4227G-2 | 2b | 2 | 3 | 0.15 | 350 | 65 | -40 | 85 | 2500 | Approved | |||||
TLP4227G | 1b | 1 | 3 | 0.15 | 350 | 65 | -40 | 85 | 2500 | Approved | |||||
TLP4597G | 1b | 1 | 3 | 0.15 | 350 | 65 | -40 | 85 | 2500 | Approved | |||||
TLP592A | 1a | 1 | 3 | 0.5 | 60 | 130 | -40 | 85 | 2500 | Approved | |||||
TLP592G | 1a | 1 | 3 | 0.12 | 350 | 30 | -40 | 85 | 2500 | Approved | |||||
TLP597A | 1a | 1 | 3 | 0.5 | 60 | 130 | -40 | 85 | 2500 | Approved | |||||
TLP597GA | 1a | 1 | 3 | 0.12 | 400 | 70 | -40 | 85 | 2500 | Approved | |||||
TLP597G | 1a | 1 | 3 | 0.12 | 350 | 40 | -40 | 85 | 2500 | Approved | |||||
TLP598AA | 1a | 1 | 3 | 0.5 | 60 | 130 | -40 | 85 | 2500 | Approved | |||||
TLP598GA | 1a | 1 | 3 | 0.15 | 400 | -40 | 85 | 2500 | Approved | ||||||
TLP797GA | 1a | 1 | 3 | 0.12 | 400 | 40 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP797JF | 1a | 1 | 5 | 0.1 | 600 | 120 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP797J | 1a | 1 | 5 | 0.1 | 600 | 120 | -40 | 85 | 5000 | Approved | Approved | ||||
TLP798GA | 1a | 1 | 3 | 0.15 | 400 | -40 | 85 | 5000 | Approved | Approved | |||||
TLX9175J | 1 | 3750 |