DS600:±0.5°C Accurate Analog-Output Temperature Sensor

Analog Temperature Sensor Is ±0.5°C Accurate Over Entire 2.7V to 5.5V Operating Voltage Range, and Wide -20°C to +100°C Temperature Range

The DS600 is a ±0.5°C accurate analog-output temperature sensor. This accuracy is valid over its entire operating voltage range of 2.7V to 5.5V and the wide temperature range of -20°C to +100°C. The DS600 can also act as a thermostat, with user-programmable trip points. A shutdown mode enables the DS600 to be placed in a low-power standby state. The DS600 is available in an 8-pin µSOP package.

Key Features
  • Accurate Temperature Monitoring Easily Added to Any System
    • ±0.5°C Accuracy (-20°C to +100°C)
    • ±0.75°C Accuracy Over Entire Temperature Range of -40°C to +125°C
    • 6.45mV/°C Output Gain with 509mV Offset at 0°C
    • Requires No External Components
    • User-Programmable Thermostat Function
  • Used In a Wide Variety of Applications
    • Power Supply Range (2.7V to 5.5V)
  • Reacts Quickly to Temperature Shifts
    • Exposed Pad 8-Pin µSOP Package for Quick Thermal Response
  • Shutdown Function Puts Device into a Low-Power Standby Mode
DS600: Typical Operating Circuit
DS600: Typical Operating Circuit
Applications/Uses
  • Cold-Junction Thermocouple Compensation
  • Portable Medical Equipment
  • Thermally Sensitive Systems that Require a High-Accuracy Analog-Output Temperature Sensor
DataSheet
titleDownload file
DS600 Data SheetDS600.pdf
Parametrics
Part NumberSensor TypeFunctionsInterfaceChannelsAccuracy
(±°C)
Parasite Pwr.Temp. Thresh.Oper. Temp.
(°C)
Package/PinsBudgetary
Price
See Notes
DS600LocalStandalone ThermostatAnalogOne0.5NoProgrammable-40 to +125µMAX-EP/8$2.06 @1k
Quality and Environmental Data
Ordering Information
Part NumberStatusRecommended ReplacementPackageTempRoHS
DS600UNo Longer AvailableDS600U+µMAX-EP,;8 pin;15.3 mm²-40°C to +85°CNo
DS600U+ActiveµMAX-EP,;8 pin;15.3 mm²-40°C to +85°CLead Free
DS600U+T&RActiveµMAX-EP,;8 pin;15.3 mm²-40°C to +85°CLead Free
DS600U/T&RNo Longer AvailableDS600U+T&RµMAX-EP,;8 pin;15.3 mm²-40°C to +85°CNo
DS600.pdf DS600
DS600.pdf DS600
DS600.pdf DS600
How Continuous Positive Airway Pressure (CPAP) Respiratory Ventilation Systems Function DS75LV
Package Thermal Resistance Values (Theta JA, Theta JC) for Temperature Sensors and 1-Wire Devices MAX31826
DS600.pdf DS600
DS600.pdf DS600